Introduction Of BPL Cardiart 6208 View 3 Channel ECG Machine
BPL Cardiart 6208 View 3 Channel ECG Machine is a medical device used to record the electrical activity of the heart. It consists of three leads or electrodes that are placed on the patient’s chest to capture the heart’s electrical signals from different angles. These signals are then amplified, processed, and displayed as a graphical representation of the heart’s activity on a monitor or printed on paper.
This type of ECG machine is generally used in clinics, hospitals, nursing home and other healthcare sectors for routine cardiac checkup, such as screening for arrhythmias, monitoring heart rate and rhythm abnormalities, and monitoring patients during medical procedures or treatments. Its compact in size and portability easy to use. it suitable for various healthcare sectors, allowing for convenient and efficient heart monitoring and analysis.
Features
- Simultaneous 3 channel ECG recording with 12 lead simultaneous acquisition and.
Large Colour LCD Display enabling the preview of ECG and preview of patient information entry.
Arrhythmia Detection in auto mode.
- High performance Li-ion rechargeable battery enables mains independent operations and provides battery use after charging.
Internal memory which allows storage of up to 500 ECGs.
The compact, light weight (only 2.5 kg) ensures device portability.
- Removes interference from power line, muscle tremor, etc. with automatic base line correction.
Facilitates transfer of ECGs from the device to USB in PDF format .
- PC interface software – Smart View Optional.
Technical Specification
General | |
Display | 3.5 inch (320X240) Colour LCD screen |
Power Supply | |
Power Supply Range | AC 100V-115V/220V-240V, 50/60Hz |
Power Consumption | 35VA |
Battery Type | Rechargeable Li-ion battery |
Battery Capacity | 3 Hours in single channel mode (with a fully charged battery 330 complete ECGs are possible in auto mode with three channel print format) |
Battery Charging Indicator | Yes |
Battery Low Indication | Yes |
Recharging Time | Approximately 5 Hours for 100% charging |
Mains Protection | Fuse: T200mA 250V |
Environmental | |
Operating Temperature | 5° to 40° C |
Relative Humidity | 15% to 95% non condensing |
Atmospheric Pressure | 700 hPa to 1060hPa |
Standards | |
Safety Standard | Compliant to Class I type CF, IEC-60601-1 and IEC/EN 60601-2-25 standards |
EMC | COMPLIES WITH IEC 60601-1-2, CISPR 11 Group1, Class A |
Others | |
Dimension | 300mm (L) x 260mm (H) x 85mm (D) |
Weight | < 2.5Kgs. |
Internal Storage | 500 ECGs |
ECG | |
ECG Leads | Standard 12 leads Sampling Frequency: 1000 Hz |
ECG Acquisition | Simultaneously 12 Leads |
Sensitivity | 2.5mm/mV, 5mm/mV, 10mm/ mV, 20mm/mV, 10/5mm/mV, AGC |
Filters | |
AC Filter | On / Off |
DFT Filter | 0.05Hz / 0.15Hz / 0.25Hz / 0.32Hz / 0.5Hz/ 0.67Hz |
EMG Filter | 25Hz / 35Hz / 45Hz / OFF |
LOWPASS Filter | 150Hz / 100Hz / 75Hz |
Signal Memory | 10 Seconds for each lead in auto mode |
Operating Modes | Manual – acquisition and printing in real time; Auto – simultaneous acquisition, RHYTHM MODE, R-R MODE |
Parameter Calculation | Yes, in auto mode (selectable) |
Keyboard | Tactile keypad |
Input Impedance | ≥50MΩ |
Frequency Response | 0.05 Hz to 150 Hz (-3dB) |
Time Constant | ≥3.2 sec |
CMRR | ≥115 dB |
DF Protection | Internal |
Printer | |
Recording System | Thermal dot matrix with Recorder”, 72mm effective print width |
Recorder Paper | Rolled Thermal Paper with Grid, 80mm X 20m |
Paper Record Speed | 5mm/sec, 6.25mm.sec, 10mm/ sec, 12.5mm/sec, 25mm/sec, 50mm/sec (±3%) |
Standard Accessories | |
Patient Cable | 1 No. |
Limb Electrodes | 4 Nos. |
Chest Electrodes | 6 Nos. |
Paper Roll | 1 No. |
Power Cord | 1 No. |
Gel Bottle | 1 No. |
User Manual | 1 No. |
Reviews